JAIST Repository >
c. マテリアルサイエンス研究科・マテリアルサイエンス系 >
c10. 学術雑誌論文等 >
c10-1. 雑誌掲載論文 >

このアイテムの引用には次の識別子を使用してください: http://hdl.handle.net/10119/9047

タイトル: Determination of trace amounts of sodium and lithium in zirconium dioxide (ZrO_2) using liquid electrode plasma optical emission spectrometry
著者: Banno, Michiko
Tamiya, Eiichi
Takamura, Yuzuru
キーワード: Liquid electrode plasma optical emission spectrometry
Zirconium dioxide
Trace element detection
Without interference
発行日: 2009-02-23
出版者: Elsevier
誌名: Analytica Chimica Acta
巻: 634
号: 2
開始ページ: 153
終了ページ: 157
DOI: 10.1016/j.aca.2008.12.021
抄録: This paper describes a quantitative measurement of trace elements (Na, Li) in high purity zirconium dioxide powder using liquid electrode plasma optical emission spectrometry (LEP-OES). Conventionally, for such type of measurements, inductively coupled plasma optical emission spectrometry (ICP-OES) is frequently employed. The detection limits of elements in zirconium by ICP-OES are degraded due to the spectra interference between the trace elements and zirconium of the matrix, because zirconium is a line rich element in spectra obtained by ICP-OES. LEP-OES is an elemental analysis method developed by the authors. The measurement principle is simple, as follows. Sample solution is put into a narrow channel on a small cuvette and voltage pulse is applied from both ends of the channel. At the center of the channel which is made narrower, the voltage and current are concentrated there, and plasma is generated. From the emission of the plasma, the quantitative analysis of the elements in the solution is achieved. The LEP-OES has the property that the emission of zirconium is relatively weak, so that highly sensitive measurement of trace elements in zirconium matrix can be conducted without interference. Sample solution is prepared by dissolving high purity zirconium dioxide powder and trace amounts of Na or Li with sulfuric acid. The voltage dependence and the pulse width dependence of optical emission spectra are also investigated. With increase of the voltage or the pulse width, the ratio of emission intensities of Na to those of hydrogen increases. This suggests that the ratio of sensitivity of two elements is variable, that means the element selectivity is controllable to some extent by the measurement conditions in LEP-OES. In the case of Na and H, the ratio can be controlled from 7.4 to 21.6%. Finally, the detection limits (3 S.D.) of the trace elements, Na and Li, in 4000 μg g^<−1> zirconium dioxide aqueous solution are found to be 0.02 and 0.133 μg g^<−1>, respectively. These values correspond to 5 μg g^<−1) for Na, 33.25 μg g^<−1> for Li in original high purity zirconium dioxide powder. The correlation coefficient of calibration curve was 0.995 for Na, 0.985 for Li. Those are comparable to the literature values of detection limits using ICP-OES.
Rights: NOTICE: This is the author's version of a work accepted for publication by Elsevier. Michiko Banno, Eiichi Tamiya, Yuzuru Takamura, Analytica Chimica Acta, 634(2), 2009, 153-157, http://dx.doi.org/10.1016/j.aca.2008.12.021
URI: http://hdl.handle.net/10119/9047
資料タイプ: author
出現コレクション:c10-1. 雑誌掲載論文 (Journal Articles)

このアイテムのファイル:

ファイル 記述 サイズ形式
14030.pdf991KbAdobe PDF見る/開く

当システムに保管されているアイテムはすべて著作権により保護されています。

 


お問い合わせ先 : 北陸先端科学技術大学院大学 研究推進課図書館情報係